VELOCICALC® PLUS Multi-Function Ventilation Meter 9565

The TSI VelociCalc 9565 series are portable, hand held, Multi-Function Ventilation Test Instruments. These

instruments are available with or without a differential pressure sensor and are designed to work with a wide

range of plug-in probes. They are designed to measure air velocity, temperature, humidity, CO and CO2.

Calculations include air flow, heat flow, turbulence, wet bulb and dew point temperature. The probes can be

ordered at any time and include a data sheet with certificate of traceability. When it is time for servicing, only

the probe needs to be returned since all the calibration data is stored within the probe.

VELOCICALC Models 9565, 9565-A, 9565-Pand 9565-X

NEW: VOC probe (Model 986)

Range: 10 to 20,000 ppb VOC, 0 to 5,000 ppm CO2
            -10 to 60°C (14 to 140°F), 5 to 95% RH

Accuracy: ±3% of reading or 50 ppm CO2, whichever is greater
               ±0.5°C (±1.0°F)1, ±3% RH2

Resolution: Up to 10 ppb VOC, 0.1 ppm CO2, 0.1°C (0.1°F), 0.1% RH

Velocity (TA Probe Models 960 and 962):

Range: 0 to 50 m/s

Accuracy: 3% of reading or ± 0.015 m/s,whichever is greater

Resolution  0.01 m/s

Velocity (Pitot Tube for Meter Models 9555,9555-A,9555-P):

Range 1.27 to 78.7 m/s

Accuracy: ±1.5% at 10.16 m/s

Resolution: 0.01 m/s

Velocity (Rotating Vane Probe Model 995):

Range  0.25 to 30 m/s

Accuracy: ±1% of reading ±0.02 m/s

Resolution: 0.01 m/s

Duct Size Dimensions:

1 to 635 cm in increments of 0.1 cm

Volumetric Flow Rate Range:

Actual range is a function of velocity, pressure, ductsize and K factor

Temperature (TA Probe Models 964 and 966,IAQProbe Models 980and 982):

Range: -10 to 60°C

Accuracy: ±0.3°C

Resolution: 0.1°C

Temperature (TA Probe Models 960 and 962):

Range: -18 to 93°C

Accuracy: ±0.3°C

Resolution: 0.1°C

Temperature (Rotating Vane Probe Model 995):

Range: 0 to 60°C

Accuracy: ±1.0°C

Resolution: 0.1°C

Relative Humidity (TA Probe Models 964 and 966,IAQProbe Models980 and 982):

Range: 0 to 95% RH

Accuracy: 6±3% RH

Resolution: 0.1% RH

Carbon Monoxide (IAQ Probe with CO Model 982):

Range: 0 to 500 ppm

Accuracy: 7±3% of reading or ±3 ppm,whichever is greater

Resolution: 0.1 ppm

Carbon Dioxide (IAQ Probe Models 980 and 982):

Range: 0 to 5000 ppm

Accuracy: 8±3% of reading or ±50 ppm,whichever is greater

Resolution: 1 ppm

Static/Differential Pressure (Probe for Meter Models 9555,9555-A,9555-P):

Range: -3735 to +3735 Pa

Accuracy: +-1% of reading +- 1 Pa

Resolution:1 Pa, 0.01 mm Hg

Barometric Pressure:

Range: 690...1240Hpa

Accuracy 2% of reading

Instrument Temperature Range:

Operating: 5 to 45°C

Storage: -20 to 60°C

Data Storage Capabilities:

Range 26,500+ samples and 100 test Ids

Logging Interval: 1 second to 1 hour

Time Constant: User selectable

External Meter Dimensions: 9.7 cm x 21.1 cm x 5.3 cm

Meter Probe Dimensions:

Probe Length 101.6 cm

Probe Diameter of Tip: 7.0 mm

Probe Diameter of Base: 13.0 mm

Power Requirements: Four AA-size batteries or AC adapter