Product Description
Probe ZS25 ZG5 Ex D ATEX:
Cylindrical vane wheel sensor / insertion probe with probe diameter 25 mm and integrated transducer UFA in Ex-d explosion proof housing. Probe materials: stainless steel, titanium.
Working temperature range up to +500 °C. Suitable for fixed measuring of actual flow velocity v [m/s] and flow rate V/t [m³/h, l/min] in clean gases and liquids, briefly also in particle-laden mediums.
Output signals:
- 4-20 mA (flow-proportional)
- quantity pulse / limit value
- HART communication
- Configurable via HART communication with HART modem adapter and PC software UCOM.
Technical Specification
Features for Probe ZS25 ZG5 Ex D ATEX:
- Measuring range: 0.3 ... 120 m/s in air/gases, 0.03 ... 10 m/s in water/liquids
- Pressure resistance: up to 10 bar / 1 MPa overpressure
- Media temperature: -40 ... +500 °C
- Media: gases / liquids
- Displayed indicators: flow velocity, flow rate, volume
- IP protection type: IP65 (connection housing)
- Type of protection: ATEX category 1/2G and category 1/2D (zone 0/1, zone 20/21)
- Sensor output: analog output 4-20 mA, limit value, quantity pulse, HART communication for configuration