The Indigo-compatible humidity probes are based on Vaisala’s proprietary HUMICAP® technology recognized for its excellent long-term stability, sensor heating for condensing environments and full recovery from condensation, insensitivity to dust and most chemicals, and chemical purge option.
HMP1 is designed for measuring ambient measurement in indoor spaces.
HMP3 is suitable for various industrial applications with moderate humidity and temperature levels in industrial HVAC systems, paint booths, cleanrooms, environmental chambers, and applications.
HMP4 is for high pressure applications, such as compressed air systems in maritime, breathing air, and industrial applications.
HMP5 is for high temperature application like baking ovens, pasta dryers, ceramics and industrial drying kilns.
HMP7 is designed for applications which involve constant high humidity or rapid changes in humidity, such as drying and test chambers, combustion air, and other humidifiers and meteorological measurements.
HMP8 is designed for pressurized applications in compressed air systems, refrigerant dryers, and other pressurized industrial applications.
HMP9 is a compact probe suitable for rapidly changing environments where a fast response time, measurement performance, and chemical tolerance are essential.
HMP80 for spot-checking and calibrating humidity and temperature measurements
TMP1 is designed for demanding temperature measurements in industrial applications, such as pharmaceutical industry and calibration laboratories.
The Indigo-compatible dew point probes are based on Vaisala’s DRYCAP® technology whose unrivalled performance is based on the capacitive thin-film polymer sensor and the auto-calibration function. Probes with the DRYCAP sensor deliver accurate measurements in the long term, dramatically reducing the need for maintenance.
DMP5 for in-line measurement in high temperature applications <180 °C (356 °F), such as in industrial drying.
DMP6 for in-line measurements in very high temperatures <350 °C (660 °F).
DMP7 for remote installations in tight spaces with measurement range to -70 °C (-94 °F). Application examples include semiconductor manufacturing equipment, industrial drying systems, compressed air systems, and dry rooms.
DMP8 for pressurized pipelines <40 bars with measurement range to -70 °C (-94 °F). Typical applications include industrial drying, compressed air systems, and applications in the semiconductor industry.
DMP80 for spot-checking and calibrating dew point measurements.
The Moisture in Oil Probe uses the proven Vaisala HUMICAP® sensor that was developed for demanding moisture measurements.
MMP8 is designed for demanding and continuous online moisture measurements in transformer and lubrication oils, hydraulic fluids, and other liquids.
Indigo-compatible carbon dioxide (CO2) probes are based on Vaisala’s unique CARBOCAP® technology that enables exceptional stability. They are ideal for applications such as incubators, greenhouses, fruit and vegetable storage and cargo, animal shelters and demand-controlled ventilation.
GMP251 for %-level measurements 0 – 20 %CO2 in life science incubators, cold storage facilities, fruit and vegetable transportation, and in all other demanding applications.
GMP252 for ppm-level measurements 0 – 10 000 ppmCO2 in agriculture, refrigeration, greenhouses, demanding HVAC applications, and for plant growth chamber manufacturers
Indigo-compatible vaporized hydrogen peroxide probes feature Vaisala’s unique PEROXCAP® technology. which enables accurate and repeatable measurement of the bio-decontamination cycle with one single probe.
HPP270 series for measuring H2O2 vapor concentration, humidity and temperature in demanding hydrogen peroxide bio-decontamination processes.